Thông số kỹ thuật:
Hãng sản xuất: TPI- MỸ
Xuất xứ: Hàn Quốc
Bảo hành: 12 Tháng
DC Volts |
Maximum Input: 1000V Maximum Resolution: 0.01mV Accuracy: +/-0.05% |
AC Volts |
Maximum Input: 750V Maximum Resolution: 0.01mV Accuracy: +/-0.4% |
DC Amps |
Maximum Input: 10A Maximum Resolution: 0.01μA Accuracy: +/-0.8% |
AC Amps |
Maximum Input: 10A Maximum Resolution: 0.01μA Accuracy: +/-0.75% |
Điện trở(Ohms) |
Maximum Input: 40MΩ Maximum Resolution: 0.1mΩ Accuracy: +/-0.05% |
Tần số |
Maximum Input: 10MHz Maximum Resolution: 0.01Hz Accuracy: +/-0.05% |
Điện dung |
Maximum Input: 4000µF Maximum Resolution: 0.01nF Accuracy: +/-3% |
Nhiệt độ (K-Type Thermocouple) |
Maximum Input: 2372°F (1300°C) Maximum Resolution: 0.1°F / °C Accuracy: +/-2% |
Kiểm tra liên tục |
Audible at less than 300Ω |
Diode |
2.7V at 1mA maximum output |
Chu kỳ |
Range: 0.1 to 99.9% Accuracy: 0.1% + 1 count |
True RMS Responding |
Có |
Giữ giá trị |
Có |
Giá trị Min/Max |
Có |
Relative Mode |
Có |
True RMS DMM with temperature, capacitance, duty cycle,
& low-pass filter.
4,000 count
True RMS for more accurate measurements
Auto/manual ranging
Temperature measurement
Duty cycle to measure the amount of time the motor is on
Low pass filter for noisy environments
Separate fuse (2) and battery compartment
IR serial interface
cULus 61010-1
CAT II - 1000V, CAT III - 600V
Model 183A Specifications | ||
---|---|---|
DC Volts | Maximum Input: 1000V
Maximum Resolution: 0.01mV Accuracy: +/-0.05% |
|
AC Volts | Maximum Input: 750V
Maximum Resolution: 0.01mV Accuracy: +/-0.4% |
|
DC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Accuracy: +/-0.8% |
|
AC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Accuracy: +/-0.75% |
|
Resistance (Ohms) | Maximum Input: 40MΩ
Maximum Resolution: 0.1mΩ Accuracy: +/-0.05% |
|
Frequency | Maximum Input: 10MHz
Maximum Resolution: 0.01Hz Accuracy: +/-0.05% |
|
Capacitance | Maximum Input: 4000µF
Maximum Resolution: 0.01nF Accuracy: +/-3% |
|
Inductance | N/A | |
Temperature
(K-Type Thermocouple) |
Maximum Input: 2372°F (1300°C)
Maximum Resolution: 0.1°F / °C Accuracy: +/-2% |
|
Continuity | Audible at less than 300Ω | |
Diode | 2.7V at 1mA maximum output | |
Duty Cycle | Range: 0.1 to 99.9%
Accuracy: 0.1% + 1 count |
|
True RMS Responding | Yes | |
Conductance | No | |
Pulse Width | No | |
Data Hold | Yes | |
Min/Max Record | Yes | |
Time Stamp Logging | no | |
Relative Mode | Yes |